LA 100-TP

LA 100-TP

  • 厂商:

    LEM(莱姆)

  • 封装:

    -

  • 描述:

    LA 100-TP

  • 数据手册
  • 价格&库存
LA 100-TP 数据手册
Current Transducer LA 100-TP For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IPN = 100 A Electrical data IPN Primary nominal rms current 100 A IPM Primary current, measuring range 0 ... ±150 A R M Measuring resistance @ TA = 70 °C TA = 85 °C RM min RM max RM min RM max with ±12 V @ ±100 A max 0 50 0 42 Ω @ ±120 A max 0 22 0 14 Ω with ±15 V @ ±100 A max 0 110 20 102 Ω @ ±150 A max 0 33 20 25 Ω ISN Secondary nominal rms current 50 mA KN Conversion ratio 1 : 2000 U C Supply voltage (±5 %) ±12 ... 15 V IC Current consumption 10 (@ ±15 V) + IS mA Accuracy - Dynamic performance data X Accuracy @ IPN, TA = 25 °C @ ±15 V (±5 %) ±0.45 @ ±12 ... 15 V (±5 %) ±0.70 εL Linearity error < 0.15 Typ Max IO Offset current @ IP = 0, TA = 25 °C ±0.10 IOM Magnetic offset current 1) @ IP = 0 and specified RM, after an overload of 3 × IPN ±0.15 IOT Temperature variation of IO −25 °C ... +85 °C ±0.05 ±0.30 −40 °C ... −25 °C ±0.10 ±0.50 tra Reaction time < 500 tr Step response time 2) to 90 % of IPN < 1 di/dt di/dt accurately followed > 200 BW Frequency bandwidth (−1 dB) DC ... 200 % % % mA mA mA mA ns µs A/µs kHz General data TA Ambient operating temperature TS Ambient storage temperature RS Resistance of secondary winding @ TA = 70 °C @ TA = 85 °C m Mass Standards −40 ... +85 °C −40 ... +90 °C 120 Ω 128 Ω 24 g EN 50178: 1997 UL 508: 2010 Features ●● Closed loop (compensated) current transducer using the Hall effect ●● Insulating plastic case recognized according to UL 94-V0. Advantages ●● ●● ●● ●● ●● ●● ●● Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference ●● Current overload capability. Applications ●● AC variable speed drives and servo motor drives ●● Static converters for DC motor drives ●● Battery supplied applications ●● Uninterruptible Power Supplies (UPS) ●● Switched Mode Power Supplies (SMPS) ●● Power supplies for welding applications. Application domain ●● Industrial. Notes: 1) Result of the coercive field of the magnetic circuit 2) With a di/dt of 100 A/µs. N° 97.10.34.000.0 14January2016/version 10 Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Current Transducer LA 100-TP Insulation coordination U d ÛW dCp dCI CTI Rms voltage for AC insulation test, 50 Hz, 1 min 2.5 Impulse withstand voltage 1.2/50 µs 7.5 Min Creepage distance 8.3 Clearance 8.3 Comparative tracking index (group I) 600 kV kV mm mm Applications examples According to EN 50178 and IEC 61010-1 standards and following conditions: ●● Over voltage category OV 3 ●● Pollution degree PD2 ●● Non-uniform field EN 50178 IEC 61010-1 Rated insulation voltage Nominal voltage Basic insulation 1000 V 1000 V Reinforced insulation 600 V 300 V dCp, dCI, ÛW Safety This transducer must be used in limited-energy secondary circuits according to IEC 61010-1. This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturer’s operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Page 2/3 14January2016/version 10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com Dimensions LA 100-TP (in mm) dCl dCp Connection IP IS RM UC UC dCl Remarks Mechanical characteristics ●● General tolerance ●● Fastening & connection of primary Recommended PCB hole ●● Fastening & connection of secondary Recommended PCB hole dCp ±0.2 mm bus bar 6.4 × 1.6 mm 3.8 mm 3 pins 0.6 × 0.7 mm ⌀ 1.2 mm ●● IS is positive when IP flows IP in the direction of the arrow. ●● Temperature of the primary conductor should not exceed IS RM 100 °C. ●● Installation of the transducer must be done unless otherwise specified on the datasheet, according to LEM U Transducer Generic Mounting Rules. Please refer to C LEM document N°ANE120504 available on our WebUsite: C Products/Product Documentation. ●● This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. Page 3/3 14January2016/version 10 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
LA 100-TP 价格&库存

很抱歉,暂时无法提供与“LA 100-TP”相匹配的价格&库存,您可以联系我们找货

免费人工找货
LA 100-TP
  •  国内价格 香港价格
  • 1+331.124361+42.96502
  • 5+303.559315+39.38832
  • 10+293.3099410+38.05841
  • 25+281.0696225+36.47017
  • 72+268.5990572+34.85205
  • 144+261.28085144+33.90248

库存:84